Low Consistency Elastomers

Low Consistency Silicone Elastomer

DESCRIPTION
  • Two-part, translucent, pourable silicone elastomer
  • Cures with heat via addition-cure chemistry
  • 10:1 Mix Ratio (Part A: Part B)
APPLICATION
  • For use in potting, encapsulating, coating, and injection or transfer molding applications
PROPERTIES
Typical PropertiesAverage Result
Uncured:
AppearanceTranslucent
Viscosity, Part A130,000 cP (130,000 mPas)
Viscosity, Part B360 cP (360 mPas)
Work Time4 hours
Cured: 3 minutes at 177°C (376°F) 
Post-Cured: 1 hour at 150°C (328°C)
Specific Gravity1.1
Durometer, Type A40
Tensile Strength865 psi (6.0 MPa)
Elongation350%
Tear Strength150 ppi (26.4 kN/m)
Tissue Culture (Cytotoxicity Testing)Pass
Elemental Analysis of Trace MetalsPass

These properties tested on a lot-to-lot basis. Please contact NuSil Technology for assistance and recommendations in establishing particular specifications.

Recommended Primer MED1-161

Note: Some bonding applications may require the use of a primer.

Packaging

37 mL Side-by-Side Kit
250 mL Side-by-Side Kit
490 mL Side-by-Side Kit
1 Pint Kit (505 g)
1 Gallon Kit (4.04 kg)
5 Gallon Kit (20.2 kg)

Warranty

12 Months

Product Profile - Full Details Product Profile
Safety Data Sheet Material Safety Data Sheet
Example packaging
Example packaging
 

WARRANTY INFORMATION

The warranty period provided by Polymer systems Technology ltd (hereinafter “PST”) is from the date of shipment when stored below 40°C in original unopened containers. Unless PST provides a specific written warranty of fitness for a particular use, PST’s sole warranty is that the product will meet PST’s then current specification. PST specifically disclaims all other expressed or implied warranties, including, but not limited to, warranties of merchantability and fitness for use. The exclusive remedy and PST’s sole liability for Packaging Warranty 50 mL Side-by-Side Kit 200 mL Side-by-Side Kit 400 ml Side-by-Side Kit 2 Pint Kit (910 g) 2 Gallon Kit (7.28 kg) 10 Gallon Kit (36.4 kg), Inc. All rights reserved. Trademarks are owned by PST or its affiliates unless otherwise noted. breach of warranty is limited to refund of purchase price or replacement of any product shown to be other than as warranted. PST expressly disclaims any liability for incidental or consequential damages.

 

WARNINGS ABOUT PRODUCT SAFETY

PST believes, to the best of its knowledge, that the information and data contained herein are accurate and reliable. The user is responsible to determine the material’s suitability and safety of use. NuSil Technology cannot know each application’s specific requirements and hereby notifies the user that it has not tested or determined this material’s suitability or safety for use in any application. The user is responsible to adequately test and determine the safety and suitability for their application and NuSil Technology makes no warranty concerning fitness for any use or purpose. PST has completed no testing to establish safety of use in any medical application. PST has tested this material only to determine if the product meets the applicable specifications. (Please contact PST for assistance and recommendations when establishing specifications.) When considering the use of PST products in a particular application, review the latest Material Safety Data Sheet and contact PST with any questions about product safety information. Do not use any chemical in a food, drug, cosmetic, or medical application or process until having determined the safety and legality of the use. The user is responsible to meet the requirements of the U.S. Food and Drug Administration (FDA) and any other regulatory agencies. Before handling any other materials mentioned in the text, the user is advised to obtain available product safety information and take the necessary steps to ensure safety of use.

 

PATENT / INTELLECTUAL PROPERTY WARNING

PST disclaims any expressed or implied warranty against the infringement of any domestic or international patent/intellectual property right. PST does not warrant the use or sale of the products described herein will not infringe the claims of any domestic or international patent/intellectual property right covering the product itself, its use in combination with other products, or its use in the operation of any process.

For Use With Low Viscosity Elastomers Medical Implants:

Biomaterials

Medical Silicones
Medical Silicones for Healthcare

SpeedMixers™

Laboratory Vacuum Mixer System
Laboratory Vacuum Mixer System

Marking Inks

Inks
Inks

Tubing

Food Medical Industrial Grade Silicone Tubing
Food, Medical & Industrial Quality Silicone Tubing