Typical Properties | Average Result |
Uncured: | |
Appearance | Translucent |
Extrusion Rate†, Part A | 60 g/min |
Extrusion Rate†, Part B | 90 g/min |
Work Time | 72 hours |
Cured: 5 minutes at 150°C (302°F). Stabilize for 3 hours minimum at ambient temperature and humidity. | |
Specific Gravity | 1.14 |
Durometer, Type A | 20 |
Tensile Strength | 910 psi (6.3 MPa) |
Elongation | 875% |
Tear Strength | 125 ppi (22.0 kN/m) |
Tissue Culture (Cytotoxicity Testing) | Pass |
Elemental Analysis of Trace Metals | Pass |
These properties tested on a lot-to-lot basis. Please contact NuSil Technology for assistance and recommendations in establishing particular specifications.
†(Performed using a SEMCO® model 250-A pneumatic gun with a ⅛ nozzle orifice and 90± 5 psi air pressure)
Recommended Primer MED1-161
Note: Some bonding applications may require the use of a primer.
Packaging
50 mL Side-by-Side Kit
2 Pint Kit (910 g)
2 Gallon Kit (7.28 kg)
Warranty